PROCESS CAPABILITY CERTIFICATION REPORT
PROCESS IS CAPABLE
Number of readings per subgroup
10
P R O C E S S I N F O R M A T I O N '01 PSW'!A21
'07 CAV'!A6
'01 PSW'!H6
'01 PSW'!A6
'01 PSW'!A14
'01 PSW'!D10
'01 PSW'!A8
Significant trends of data points:
X Chart
R Chart
LOCATION Plant
Dept:
Quality Date:
2013-4-10
Increasing RUN LENGTH 34PART Part number:Part description N/A HOW MANY RUNS 31Drawing number Eng. chg. level N/A Decreasing
RUN LENGTH 33TOOL
Tool number # Cavities
HOW MANY RUNS
32DIMENSION
Description Units
10
Out of control limits
00SPEC
12.7
PLUS 0.25MINUS
0.25Consecutive data points above avg.52Lwr Spec Limit
12.45NOMINAL 12.7
Upr Spec Lim
12.95
Consecutive data points below avg.
4
4
12.7384
12.7005
23456710111213141516171819202122232425
12.6626
12.62
12.
12.66
12.68
12.7
12.72
12.74
12.76
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Average (X chart)
Data Values UCLx AveX LCLx
0.2187
0.1231
2
3456710111213141516171819202122232425
0.0
0.05
0.1
0.15
0.2
0.25
1
23
4
56710111213141516171819202122232425
Range (R chart)
Data Values
UCLr
AveR
LCLr
Two sided spec (bilateral)
One sided (MIN)
One sided (MAX)