WITHSTANDING VOLTAGE TEST (13.3) | N/A Fail Pass | ||||
The appliance is disconnected from the supply and the insulation is immediately subjected to the test. Duration 1 min | |||||
Test Location | Type of Insulation | Working Voltage (V) | Test Voltage (V) | Break down | |
Live parts and enclosure | RI | 240 | 3000 | Yes No | |
Live parts and output terminals | RI | 240 | 3000 | Yes No | |
Yes No | |||||
Yes No | |||||
B = basic insulation S = supplementary insulation R = reinforced insulation Cut off current 100 mA | |||||
EQ No.: |
ELECTRIC STRENGTH TEST (16.3) | N/A Fail Pass | ||||
Duration 1 min | |||||
Test Location | Type of Insulation | Working Voltage (V) | Test Voltage (V) | Break down | |
Live parts and enclosure | RI | 240 | 3000 | Yes No | |
Live parts and output terminals | RI | 240 | 3000 | Yes No | |
Transformer | RI | 240 | 3000 | Yes No | |
One layer of insulating tape | SI | 240 | 1750 | Yes No | |
B = basic insulation S = supplementary insulation R= reinforced insulation Cut off current 100 mA | |||||
EQ No.: |