视频1 视频21 视频41 视频61 视频文章1 视频文章21 视频文章41 视频文章61 推荐1 推荐3 推荐5 推荐7 推荐9 推荐11 推荐13 推荐15 推荐17 推荐19 推荐21 推荐23 推荐25 推荐27 推荐29 推荐31 推荐33 推荐35 推荐37 推荐39 推荐41 推荐43 推荐45 推荐47 推荐49 关键词1 关键词101 关键词201 关键词301 关键词401 关键词501 关键词601 关键词701 关键词801 关键词901 关键词1001 关键词1101 关键词1201 关键词1301 关键词1401 关键词1501 关键词1601 关键词1701 关键词1801 关键词1901 视频扩展1 视频扩展6 视频扩展11 视频扩展16 文章1 文章201 文章401 文章601 文章801 文章1001 资讯1 资讯501 资讯1001 资讯1501 标签1 标签501 标签1001 关键词1 关键词501 关键词1001 关键词1501 专题2001
电源安规详细条款
2025-09-30 15:27:23 责编:小OO
文档
OSM/EE(Chm)8/03 Standard EN 60 950 3rd Edition and EN 60950-1

This List of Decisions is the outcome of the CENELEC Operational Staff Meeting for Electronic Equipment (OSM/EE). The decisions are designed to assist with common application of the Standard and not to change the meaning of the standard, which remains the definitive document

This list contains also items related to EN 60950-1 where specified under "comments". If other decisions can also be used for EN 60950-1 has to be verified.

Clause Decision Comments Dec.

No. Ref. Doc. Item

of

Doc.

Testing of an LCD TV with external power supply unit. The set needs to be certified according to IEC 60065 ed 6. The external power supply is already certified according to IEC 60950 another certification body

The LCD TV may be used as a monitor as well.

The intention of the manufacturer is to put the LCD screen/monitor and the power supply together on the market.

Case 1: LCD multimedia screen with a built in PSU (pre-certified),.

The whole apparatus has to be tested to one standard either EN 60950 or EN 60065 together with IEC Guide 112 as the product is a multimedia equipment (having an antenna and a telecommunication connection). Is a part of the apparatus already certified ( for example, PSU) this part has to be reassessed to the standard used for the whole apparatus either EN 60065 or EN 60950.

If there is sufficient detail available of the test results for the existing certification, it might not be necessary to carry out full testing to the second standard..

Case 2: Multimedia screen with separate PSU (pre-certified): a) If the manufacturer intends to sell the combination (Screen plus PSU) together, the PSU has to be listed in the Test Report and both items of apparatus have to be assessed according the same Standard.

b) If the manufacturer does not intend to sell the screen together with a specific PSU, it has to be mentioned in the test report what kind of PSU was used during the tests and the limits for voltage and current have to be specified. 02/5

EE(Chm)

3/02

7.1

CCA certificate can be issued for separate power supply units for office machines and information technology equipment which are tested according to Publication EN 60950. Sweden: The kind

of information

supplied with the

unit shall include a

statement that the

unit is intended for

office

machines/equipm

ent only.

Germany: The

above information

has to be in the

Users Manual.

95/6 EA(FI)

3/91 4.14Products similar to previously certified products shall be covered by an Addendum to the base report.

The CCA format shall be used where possible. The CCA cover page should always be used. Addendum reports

should be derived

from a base

report, not an

already derived

report.

EA(GB)3

/93 5.1

The primary testing laboratory may check National deviations in the case of the CCA.

In the case of the CB scheme, the CB Bulletin provides the individual requirements of each Certification Body. EA(GB)3

/93 6.27

Plug with integrated Power Supply

The equipment has to have a complete marking as for a power supply.

If the marking is on a part of the enclosure which is gripped while pulling/inserting the device from/into a wall socket outlet, additional requirements for the durability of the marking are necessary.

For the time being the meeting decided to use the marking requirements of EN 50144-1 "Safety of hand-held electric motor operated appliances".

Safety instructions shall state clearly that a replacement with a normal plug will be hazardous. 97/2 EE(Chm)

5/97

7.5

Where equipment tested to the current version of the standard incorporates a subassembly (e.g. a power supply unit ) certified to an earlier version of the standard (which is still valid for production ), the equipment test report shall clearly identify the version against which the subassembly was initially assessed. In determining any additional tests, consideration shall be given to the application, such as location and orientation. Also applicable changes in the standard shall be taken into consideration 97/9

EE(Chm)

5/97

7.1

1. 2. 4.3 If the safety strategy of an equipment containing SELV and

TNV circuits relies on Protective Earthing this equipment is

considered to be Class I and not Class III. 97/4

EE(Chm)

5/97

9.1

1. 5 RFI filters having components meeting IEC 60384-14 are

accepted. EA(GB)3

/93

6.7

1. 5. 1 A resistors which is connected across the mains or between

the mains and the safety earth do not need to comply with

EN 60 065. If the resistor is accepted according to EN 60

065, it need not be short-circuited during fault condition tests

in § 5.4.

This decision (96/14) does not apply to resistors bridging

double or reinforced insulation. See 1.5.7.2 96/14

00/7

EA(FI)

1/91

EE(Chm)5

/96

4.4

10.11. 5. 1 Capacitors which are connected after a rectifier in a primary

circuit of a switch mode power supply unit need not be se-

parately approved.

"In a primary circuit before a rectifier there is installation

category III for Permanently Connected equipment, therefore

class X1 capacitors must be used.

In a primary circuit before a rectifier there is installation

category II for Pluggable equipment Type A and Pluggable

equipment Type B, therefore minimum class X2 capacitors

must be used. The use of a mains fuse, a mains filter or a varistor cannot be a method to reduce installation category." Secondary circuits are normally in installation category I when the primary is in installation category II. However, a floating secondary shall be subject to the requirements for primary circuit in table III unless separated from primary circuits by an earthed metal screen. Changed acc.

discussion by mail

See also 2.10.3.4

EA(FI)

1/91 4.1.2

1. 5. 1 Varistors across the mains

Accepted by all countries (when the varistor is separately

certified)

Varistors across the mains with a protective device to guard

against short-circuit.

Accepted by all countries (whether the varistor is separately

certified or not)

Varistors between the mains and the protective earth:

1. For Pluggable equipment, type A:

Accepted by all countries (when the varistor is separately

certified)

except

Austria, Belgium, Denmark, Finland, Germany, Norway,

Sweden, United Kingdom

2. For pluggable equipment Type B and permanently

connected equipment, connected to protective earth:

Accepted by all countries(when the varistor is separately

certified)

A combination of a varistor(when the varistor is separately certified) in series with a spark gap /Gas-Tube (the varistor need not be separately certified) between the mains and the protective earth and with a protective device to guard against short-circuit:

1. Pluggable equipment Type A:

Accepted by all countries

2. Pluggable equipment Type B and permanently connected equipment:

accepted by all countries

NB: Where the term "separately certified" is applied to a varistor in the above, this means that the varistor is

separately certified according to Publications IEC 61051-1

98/2

95/10

EA(FI)

1/91

EE(Chm)

1/94

EE(Chm)

3/03

EE(Chm)5/

98

EE(Chm)

3/03

EE(Chm)5/

95

4.3

6.10

6.18

6.2.1

9.5

6.2.1

9.5and IEC 61051-2 or according to CECC 42200.

Varistors (VDR`s) may burn or burst during life-time due to an increasing temperature stress caused by increase of leakage current with a number of switching cycles in the VDR. This is suitable protected where a gas-filled surgearrestor (gas tube) is in line with the VDR. In circuits where no gas tube is required a thermal interrupting device on the VDR connected in series with the VDR is to be provided. Compliance criteria ref. sub clause 5.3.8.1”

1. 5. 1 The following table should be used as guidance when

assessing the use of CSA and/or UL type fuses in

equipment:

Fuse rating (A) Max S/C Current (A)

1 or less 35

1 to 3.5 100

3.5 to 10 200

10 to 15 750

15 to 30 1500 Table derived from

CSA248.14/UL248

.14 Clause 5.5

Table A

EA(GB)

3/93 6.6

1. 5. 1. We may accept resistors on the primary side to be

used as ”protective device”, provided that they comply

with all the following conditions

-it shall operate satisfactory when the appliance is tested

according to EN 60950. Compliance is checked by repeating

at least 10 times, each case with a new resistor during worst

case fault condition test, when the appliance is directly

connected to the mains. The resistor may not interrupt with

explosion or spark/flame which are not in compliance with the

standard.

-Not accepted in operator access area

-The resistor is to be listed as critical component in the test

report.

-Identification using part number or the like is to be located

adjacent to the resistor, or use of cross-reference in the

service documentation as described in 1.7.6, last paragraph.

-the component shall be available as spare part in the country

where the appliance is sold.

And in addition a data sheet is provided showing all the

relevant data for the resistor 99/1

EE(Chm)7/

99

9.11. 5. 2 Subject: acceptance of UL/CSA certified units in

end-use racks/equipment

When evaluating end-use equipment like large

telecom racks composed by several units

("drawers") for building-in like computer

machines, modems, routers etc., for national mark

certification or ENEC or IECEE/CB, the separately

approved units (computers, modems etc.) bearing a

CCA mark are accepted with limited investigation

(e.g. consisting in the check of compatibility of

the certification Ambient temperature with the

end-use equipment specified ambient; input voltage

rating with the one of the end-use equipment

etc.); they will then subjected to the end-use

equipment tests (e.g. electric strength, total

leakage current, capacitor discharge etc).

Which is the delegate position in regard to the

acceptance of UL Listed or CSA Certified drawers

(no CCA mark, no CB report) in such racks when the

certification Standard was UL 1950 3rd edition

(based on IEC 950 2nd Ed) or UL 60950 (based on

IEC 60950 3rd Ed) as long as all the differences

between the UL requirements and the IEC based

Standard and between the IEC based Standard and

the current IEC Standard used for the end-use

equipment have been checked and satisfied?

All critical components have to be certified to the relevant

EN or IEC component standard. Acceptance of components

has to follow CCA /228-1 "Recognition of components"

In the special case mentioned, we need a test-report and a

certificate showing compliance to EN 60950 EN 60950:1999 and

EN 60950-1:2000

02/11 EE(Chm)

3/02

10.3

1. 5. 6. There is no need for a CCA approval for every single

component. There should be sufficient documentation of

the certification of the component and the IEC or CENELEC

standards used. Nevertheless the appropriate use of the

component has to be checked.

For Capacitors the edition of the standard should be given 95/1 EE/Chm)

5/95

5.1.2

1.. 5. 7.1 Capacitors certified to IEC 60384-14 1.ed will be accepted

for 5 years after DOW of EN 132400 .

Capacitors certified to IEC 60384-14 2.ed and/or EN132400 are acceptable .

Y1 and Y2 capacitors are accepted across basic insulation

Y1 and Y2 capacitors are accepted across supplementary insulation .

The enclosures of Y1 capacitors are considered to comply

with the requirements for reinforced insulation with the exception of the area near to the leads where the insulation becomes thinner

95/9

97/1 EE(Ch m)5/95 EE(Ch m)5/97 9.3

3.

1. 5. 7.2

Is it possible to bridge a TNV barrier with one resistor/ two resistors?

Subclause 1.5.7.2 establishes the principle that two resistors can be connected in series across a double / reinforced insulation provided the are the same value, they each comply with the creepage and clearance

requirements and the accessible circuits comply with the Limited current circuits requirements.

Subclause 6.1.2.1 indicates that components across the barrier can be removed during the electric strength test provided the circuit complies with the 10mA limit during the test described in figure 6A.

One resistor across the TNV barrier is allowed provided that the tests of Scl. 6.1.2.1 and 6.2 are passed and the

requirements for creepage distances and clearances and the requirements of Scl. 5.1.8 are fulfilled.

02/12 EE(Chm)3/02

10.4 1. 7.

1 If the rated voltage marked on the equipment exceeds

250V then the components should also be suitable for this voltage. 96/2

EE(Chm)5/96

6.6 1.

7.

1 Laptop computers, which are supplied by SELV and in

which hazardous voltages are generated, cannot be Class III and therefore must be Class I or Class II. If they are designated Class II, the double square symbol shall be required.

It was agreed that a

lap-top or notebook computer supplied from SELV circuits and in which circuits at voltages which exceed 42.4 V peak or 60V DC

complying as limited current circuits is considered to comply with the

definition of Class III equipment

EA(FI) 3/91 EE(Chm)1/94 4.11

6.12

1. 7.

1 Only the set one voltage of an internal voltage regulating

device should be indicated on the outside

EE(Chm)1/94

10.3

1. 7. 1 Safety related components shall be marked with a trade

mark (logo) and an identification number or code. For a

component without independent certification that is

dedicated for use in one or more specific models the

identification may be in a form of a code 00/8

EE(Chm)5/

00

10.5

1. 7. 2 Safety relevant documentation has to be as a hardcopy.

The Users Manual may also be on a diskette 95/11

EE(Chm)5/

95

9.7

1. 7. 2 A Class III equipment with an enclosure made of HB-

material and using a non-special connector for the

AC/DC input has to have a marking stating the

following:

"For use only with power supply MANUFACTURER,

MODEL"

This statement shall also be in the user-instructions.

Alternative marking:

"Use only power supplies listed in the user-

instructions"

or

"For applicable power supplies see user-

instructions"

This statement shall also be in the user-instructions.

The user instructions must then have a listing of

manufacturer and model of the relevant power supplies.

Method 2 of 4.7.1 of EN 60950:2000 is recommended. 99/2

EE(Chm)7/

99

EE/Chm)

1/2001

9.3

6.2

1. 7. 6 The wording "special fusing characteristics" includes

braking capacity. To be able to accept one fuse marking in

Europe, in the USA and in Canada, markings "mA" and "A"

can still be accepted. Therefore the following kind of

markings are accepted:

T315mA L F4A H

250 V 250 V EA(FI)

1/91 4.5

1. 7. 8.3 It is not acceptable to mark "I" and "0" on a functional

switch of a lap-top or notebook computer where for

example the charging circuit is energised at all times.

No marking at all is acceptable.

The marking “POWER” is not acceptable. 99/3

EA(GB)3/9

3

EE(Chm)

6.3

9.4

1. 7. 12 Testing houses shall put a note in the test report

mentioning in which language the markings regarding

safety has been checked.

Safety markings in all official languages of CENELEC

countries need not be checked when the CCA certificate is

issued. EA(FI)

3/91 4.15

1. 7. 15 Lithium batteries included in integrated circuits are not

considered as replaceable.

There must be an advise in the service manual concerning

the disposal of these parts. 95/13

EE(Chm)5/

95

9.8.2. 1. 1 A modem-card if it is separately sold and intended for use

in operator access areas, has to be tested for the relevant

protection of TNV-circuits 99/4

EE(Chm)7/

99

9.5

2. 1. 1.4 Double or reinforced insulation shall also be required

between wires in SELV circuits and metal parts with

hazardous voltages inside the equipment.

EA(FI)

3/91

EE(Chm)1/

94

4.1.5

6.13

2. 1. 2 Products which are considered completely hazardous when

covers are removed do not need additional protection e.g.

monitors. Opening of an enclosure of a monitor is

considered to be intentional because inside the equipment

there are not parts which need servicing, but repairing. EA(FI)

3/91 4.5

2. 2. 4 SELV circuits can be connected to non-SELV circuit if the

equipment still complies with the requirement of Scl. 2.2 in

case of single fault condition. EA(FI)

1/91 4.10

2. 2. 4. DC centralized battery systems Voltage in

Telecommunication Central offices:

Following the IEC TR 62102, Annex B, a 75 V dc stationary

battery system is considered TNV 2 and double or

reinforced insulation from the mains is required. The

installation instructions should provide guidance on how to

ensure that the system will not become hazardous after a

single fault according to 1.7.2.” Confirmed by

WG7 of TC108

03/5 EE(Chm)

3/03

5.1.9

2. 2. 5 Until the standard is changed condition 2 to table 9 should

be read as follows:

Overcurrent protective devices within the equipment shall

be bypassed in turn. TO BE

RECONSIDERED

95/19 EE(Chm)5/

95

9.17

2. 4. 2 When checking the frequency and for the calculation of the

maximum peak current the frequency measured when the

circuit is loaded with a 2000 Ohms resistor is considered to

be the value to be used. IEC-TC74/WG8 is

of the same

opinion.

EE(Chm)1/

94 10.7

2. 4. 2 As already covered in the above decision 2.4.2 from 1994 the

maximum peak current and the frequency measured when

the circuit is loaded with the 2 kOhm resistor has to be

considered. If there is still a second frequency (envelope

waveform) the most unfavourable value has to be taken into

account .

In the case mentioned 330 Hz is the decisive frequency.The chairman of

TC74WG5 advised to

use the measuring

network of Annex D

Figure D.1 which

takes all frequency-

problems into

account. He is

preparing a paper on

the problems of

different frequencies

in touch currents. I

will circulate that

paper as soon as it is

available.

00/9 EE(Chm)5/

00

10.9

2. 5 Higher voltages are not allowed (Tables 2B and 2C to be

followed). Behind a limited power source higher voltages

can be created within secondary circuits out of the low

voltage output of the limited power source. HB material is

possible, even if there is for example a 1000V back-light

source. However, an assessment has to be made to ensure

that there is no fire or ignition hazard. 98/5

EE(Chm)5/

98

9.14

2. 5

Limited Power Source (Battery supplied equipment) Battery supplied equipment with an enclosure of HB-material shall only be used with batteries that are in compliance with LPS. Alternative batteries on the market may not comply with LPS limits, and shall therefore not be used with such equipment.

With reference to the decision 99/2 to 1.7.2 for use of alternative Power Supplies (ref. below), it is proposed to consider a similar decision for alternative batteries for battery supplied equipment with an enclosure of HB-material.

Battery supplied equipment with an enclosure of HB-material has to have a marking stating the following, as the battery is to comply with the requirements for LPS:

"For use only with battery MANUFACTURER, MODEL" This statement shall also be in the user-instructions .

Alternative marking:

"Use only batteries listed in the user-instructions" or

"For batteries see user-instructions "

This statement shall also be in the user-instructions.

The user instructions must then have a listing of manufacturer and model of the relevant batteries .

02/13

EE(Chm)3/02

10.7 2. 6

It is acceptable to use a track on a PCB as the safety earth path, provided it meets the requirements of the relevant tests.

EA(GB)3/9

3

6.10

2. 6.

3.3 Subject: protective bonding conductor test current and

duration for DC powered equipment rated in excess of 16 A

Sub clause: 2.6.3.3/2.6.3.3/2.6.3.4

Question:

The referenced Standards indicate that the protective bonding conductor test current and its duration for DC powered equipment are specified by the manufacturer when the current rating exceeds 16 A.

Which are the minimum current and time values we should accept for such test ?

The current rating of the circuit means the current rating of the protective device (See meeting of WG8 of IEC TC74 in Helsinki).

When the manufacturer specifies a test current and duration, that current and duration shall first be used to check that the protective device will operate in this condition. If the

protective device does operate, the test current and duration specified by the manufacturer shall be used to test the protective bonding conductor. If the protective device does not operate, the testing laboratory shall ask the manufacturer to specify a more suitable combination of test current and duration.

IEC60950:1999 and IEC60950-1:2000 02/14 EE(Chm)

3/02

10.8

2. 6 5.7 Internal connections for earthing continuity purpose achieved by one rivet in combination with a lock washer are acceptable.

EE(Chm)1/94

10.8

for fuse-links inside the equipment are as follows:

Pluggable Equipment Type A

Denmark 16 A

Finland 16 A

Norway 16

A

Sweden 16

A

Switzerland 10

A

United Kingdom 16 A EA(FI)

3/91 3.4

2. 7. 4 Two protective devices may be required in equipment

intended to be connected to an IT power system. In Norway IT

power system is

used. However,

only one

protective device

can be accepted

there.

EA(FI)

1/91 4.7.1

2. 7. 4 One fuse is acceptable based on the judgement that the

installation fuse could protect the appliance in every earth

fault case EE(Chm)1/

94 10.8

2. 10. Partial discharge test, VDE 0884, is not accepted for the

time being. EA(FI)

3/91 4.1.1

2. 10. The insulation of an accessible LED which is connected to

hazardous voltage shall fulfil the requirements of Clause

2.10, but is not tested with the steel sphere.

The foil of a membrane switch is allowed to be used as

insulation against hazardous voltages if the mechanical

construction provides sufficient strength and lifetime. EE(Chm)1/

94 10.10

2. 10. The insulation between the heat sink and the current

carrying parts of an electronic component (oxide layer) can

only be considered as functional insulation. EE(Chm)1/

94 10.11

2. 10. The insulation of the outside of a capacitor according to IEC

60384-14 2.ed. fulfils the requirements for basic insulation.

For reinforced insulation the distance requirements of EN

60065 and EN 60950 must be fulfilled 95/8

EE(Chm)5

(95

8.2

2. 10 Insulation between parts directly connected to the mains in

front of a fuse has to fulfil the requirements for operational

insulation or pass the test of 5.3.4 b). 95/14

EE(Chm)5/

95

9.12

2. 10. For judging distances (combination of creepage and

clearance) from the high voltage connection of a CRT table

2Kor, according to subclause 2.1.1.1 (Paragraph after Note

4) the dielectric strength test is to be used.

Reinforced insulation is required to the outer surface of an

enclosure (when of insulating material) and operational

insulation is required to an internal, earthed part. 95/15 EE(Chm)5/

95

9.12

2. 10 According to

3.1.4 the insulation of primary and secondary

lead outs need only to fulfil the dielectric strength test. 95/16

EE(Chm)5/

95

9.13

2. 10. 1 Force of 10 N shall be applied to all internal parts whether

they are accessible or not. (See 4.2.2) EA(FI)

3/91 4.1.6OSM/EE(Chm)8/03 Standard EN 60 950 3rd Edition and EN 60950-1

Clause Decision Comments Dec.

No. Ref. Doc. Item

of

Doc.

2. 10. 2 In a transformer the highest occurring working voltage is the

basis for insulation requirements. Outside the transformer

the actually measured voltage is used . If two or more

secondary windings are connected together even outside

the transformer the actually measured voltage on each

winding is the basis for insulation requirements provided

that the relevant windings are insulated from each other

inside the transformer.

If the secondary voltage is not accessible only functional

insulation is necessary. EE(Chm)1/

94 10.5

10.6

2. 10. 2 There is an LC ignitor for a high pressure lamp. The open

output voltage of the ignitor is as indicated in the

figure.

One ignition cycle takes approx. 4 seconds. During these

4 seconds Upp is approx.

5 KV during max. 1 second. after

1 second the voltage decreases to approx 500 Vpp and

after the 4 seconds the cycle stops (no output).

If a lamp is connected and ignites the cycle will stop

immediately, the normal lamp output voltage is approx.

Question:

Do delegates agree with the proposal for Amd 1 of IEC

60950-1 and therefore see the described signal as a

starting pulse and its rms value not taken into account

when determine the minimum creepage distance.

If so, what about the pulse duration? Is e.g a pulse

duration of 5 seconds acceptable or 10 seconds ?

“At the moment it is advised to use the table of IEC/EN

60926."

We have to take into account repeatable high voltage if the

lamp does not conduct (during start or in fault conditions)” The ongoing work in

TC74 WG6 (now

TC108-74TT-

WG6)will be

monitored. The

latest paper will be

distributed for

information.

02/18 EE(Chm)

3/02

12.4

2. 10. 4 Table 2L stops at 1kV working voltage for Pollution degree

2 and 3. For higher voltages Table 4 of HD 625.1 S1 (IEC

606-1) has to be used 98/4

EE(Chm)5/

98

9.9

2. 10. 4 In a 5V circuit on the primary side of a switched mode

power supply, having a direct connection to the mains (230

V ac), the working voltage to be used for table 6 is 250V ac.

If the working voltage is lower than 250V it is seen as 250V.

If it is higher, distances have to be calculated according to

2.10and where a higher working voltage than the mains

voltage (250V) is present, higher requirements for creepage distances, clearances and insulation (high-pot) tests have to be taken into account. 97/10

EA(GB)3/9

3

EE(Chm)5/

97

6.11

9.8OSM/EE(Chm)8/03 Standard EN 60 950 3rd Edition and EN 60950-1

Clause Decision Comments Dec.

No. Ref. Doc. Item

of

Doc.

2. 10.

3.2 Table 2J stops at 1300V repetitive voltage. For higher

voltages extrapolation of the table is possible. 98/3

EE/Chm)5/

98

9.8

2. 10. 5 The plastic enclosure of a semiconductor can be

considered as basic insulation. These components

including alternatives must be listed in the list of critical

components and there must be a remark in the service

documentation 95/17

EE(Chm)5/

95

9.14

2. 10. 5. Requirements for a tape for insulation:

Based on cl 1.3.4, when an adhesive is required to maintain

a level of safety (e.g. adhesive tape), then it is

recommended to apply the cl 4.6.5. Provisional, waiting

for TC108/MT2

confirmation

03/7 EE(Chm)

3/03

12.4

2. 10. 5.1 Insulation between semiconductors (mains) and heat sinks

Either a second sheet is required or it must be checked

whether the distance through insulation has to be increased

to comply with the requirements of clauses 4 and 5. 95/7

EE(Chm)5/

95

8.1

2. 10. 5.2 2.10.5.2 is not to be used for winding wires only 2.10.5.4.

applies. 96/15

EE(Chm)5/

96

10.2

2. 10. 5.2 The tests on non-separable 3-layer foils are done on a

separate sample using a test voltage of 4,5 kV (3*1,5 kV)

for reinforced insulation Decision made in

the 37.meeting of

TC74 WG6 in

Stuttgart

EE(Chm)5/

00

TC74/WG

6(Secretar

y) 25

12.3

37.9.1

2. 10. 8. The requirements for distances through insulation are to be

applied to lateral separation between layers provided that

the thermal cycling test is passed 95/2

EE(Chm)5/

95

5.1.7

2. 10. 5.4 2.10.5.4 could also be used for similar insulation materials

than polyimide as long as they comply with the tests of

Annex U. 96/16

EE(Chm)5/

96

10.2

3. 4. 2 In a pluggable equipment the mains plug can be considered

as a disconnect device. Disconnect device shall either be a

double pole mains switch (IT power system: all-pole mains

switch) or a mains plug.

Therefore in a pluggable equipment a single pole mains

switch or a micro switch can be accepted. In a pluggable

equipment a semiconductor or a combination of

semiconductors can perform functional switching for stand-

by operation. EA(FI)

1/91

4.8

and

4.9

4. 3. 4 Force of 10 N shall not be used for testing the compliance

of § 4.3.4 . Securing of wires is important. The natural

movement of the components shall be taken into account. EA(FI)

3/91 4.8

4. 3. 4 A heat shrinkable tubing is an acceptable means for

additional securement to single clamping or soldering of

internal wiring, but not for the termination of the mains cord. 95/4

EE(Chm)5/

95

5.1.11

4. 3. 5 If there is a possibility of mis-mating of modular connectors

(e.g. RJ-11, RJ-12 etc.) accessible for the user, tests have to

be made to verify that the SELV limits remain.

If the voltage of the TNV-circuit is known this value is used,

otherwise the test generator of 2.3.5 (Figure 2E) is used for

testing. 98/6

EE(Ch

m)5/98

9.14

4. 3. 6 Every NTR concerning an equipment with plugs as part of

the enclosure shall have additional information about the

tests made on the plug. The circulated 2 pages gives an

example, for class II plugs. Class I plugs shall be handled

accordingly. 96/10

EE(Ch

m)5/96

8.1

4. 3. 8 The requirements for lithium cells apply to separate devices

such as memory cards, remote control units etc. EA(GB)3

/93 6.18

4. 3. 8 When calculating the reverse current the voltage of the

battery is considered to be zero. 95/13

EE(Chm

)5/95

9.8.

4. 3. 13 If one type of display tube has been tested for ionising

radiation, similar types can be accepted without test. The

ionisation test shall be carried out under normal operating

conditions. EA(GB)3

/93

6.16

4. 3. 13 For apparatus comprising a laser product the class, the

laser-data and the relevant warning marking shall be stated

in the test report 96/4

EE(Chm)

5/95

EE(Chm)

5/96

10.12

6.22

4. 4. If it is clearly evident that there are no hazardous moving

parts, then marking detailed in this clause is not required. EA(GB)3/9

3 6.32

4. 4. 2 Protection in Operator Access area

Small spinning fans (typically 5-8 cm size), in User

Accessible area may be evaluated different due to 4.4.2,

consideration of hazardous moving parts. The access to

the fan may be directly from the outside, or when opening

a door or cover.

What should be the criteria for when access to such a

small spinning fan is considered as hazardous moving

part, requiring a guard? (Speed, sharpness of blades etc.

causing possible injury to e.g. fingers)

EN 60335-2-80 specifies the following:

Scl.: 20.101:

Fan blades, other than those of fans for mounting at high

level, shall be guarded unless their leading edges and tips

are rounded and

- they have a hardness less than D 60 Shore, or

- they have a peripheral speed less than 15 m/s when the fan is supplied at rated voltage, or

- the fan has a power output not exceeding 2W when

supplied at rated voltage.

NOTE: An edge with a radius of not less than 0,5 mm is considered rounded.

Compliance is checked by inspection and by measurement 02/20

EE(Chm)

3/02

10.10

4. 5 The original, not a copy, of CCITT test form No 3 shall be

used at the heating test in normal use of telefaxes.

An alternative means is the Test Form Nr.4 named "Black-

White facsimile test chart BW01 (ITU-T test chart No,: 4) 98/1

EA(FI)

3/91

EE(Chm)5/

98

5.2

4. 5 A thin plastic coating (spraying) on the external surface of

the metal enclosure is not taken into account when

determining the temperature rise on touchable metal parts. EA(FI)

3/91 4.3.2

4. 5 For the heating test requirements of optocouplers,

reference should be made to manufacturer's data for

maximum operating temperature as well as manufacturer's

data for input and output currents. It should be ensured

that the optocoupler is operating within it's design

parameters. EA(GB)3/9

3 6.244. 5 a) A declaration with adequate information from the

equipment manufacturer is accepted to classify insulating

materials.

b) Information from the UL-Yellow-Book may be taken into

account.

c) In the case of different insulating systems the material

with the lowest operating temperature is governing the total

operating temperature of the system 95/22

EE(Chm)5/

95

9.21

4. 5 For the acceptance of coils of RFI filters Table 16 condition

5 should be taken into account.

With reference to Condition 5 of Table 4A temperature

limits on individual coils, being part of RFI filters, can be

accepted according to component rating. 98/7

EE(Chm)5/

98

9.15

4. 6. 1 The requirements of this Sub-clause are applicable to the

fire enclosure and the electrical enclosure. EA(GB)3/9

3 6.17

4. 6. 2 Following construction is accepted:

There are openings in the bottom of a fire enclosure which

are larger than 40 mm². Above these openings there is a

printed board which is horizontally mounted. The

components are on the upper side of the printed board. The

printed board fulfils the requirement of V-1 material. This decision is

applicable to

equipment with a

mass exceeding

18 kg. Compliance

clause in 4.6.2

covers this

problem

EA(FI)

1/91

EE(Chm)5/

96

4.12.3

6.25

4. 6. 2 It is acceptable to have a printed circuit board (above a fire

enclosure having holes greater than 40mm²) having holes of

less than 40mm², if the components close to the holes

comply with flammability class V1. EA(GB)3/9

3 6.21

4. 6. 5 Compliance is checked by examination of the construction

and of the available data. If such data is not available,

compliance is checked by the following tests.

1. What documentation is required? E.g. description

of the materials from which the adhesive is composed +

test results of a cyclic test of 600 hours at -30°C to

+70°C.

Is this sufficient for parts not subject to heat?

2. Is a UL 746C (Polymeric Materials - use in

electrical evaluation) approved adhesive acceptable?

3. Is a prove as resistance to heat at 90°C (UL RTI

90, QMFZ2) sufficient?

Other

We do not have sufficient experience to be sure that any of

the suggested conditions or tests in item 1,2 or 3 above are

equal to or better than the requirements in 4.6.5 or 4.3.22.

Available data have to prove compliance with the

requirements of 4.3.22 or 4.6.5. If not the relevant tests have

to be applied. 02/17

EE(Chm)3/

02

12.1OSM/EE(Chm)8/03 Standard EN 60 950 3rd Edition and EN 60950-1

Clause Decision Comments Dec.

No. Ref. Doc. Item

of

Doc.

4. 7 Declaration of used materials with adequate information

from the equipment manufacturer is acceptable.

Furthermore, the flame resistance of plastic materials listed

in the UL Yellow Book can be taken into account when

checking the compliance with § 4.7.3

In the flammability assessment of PCB's a declaration that

the manufacturer uses V0 or V1 rated PCB's as required is

acceptable.

The test report should detail material manufacturer, type

reference and flammability rating as a minimum for other

materials

In cases where the equipment manufacturer is unable to

obtain the appropriate information, due to the unwillingness

of the component manufacturer to divulge proprietary data,

acceptance may be based on a Certificate of Conformity, or

written declaration, from the component manufacturer,

detailing the flammability rating of the plastic materials. Note: This exception is not allowed for enclosure materials, which must also meet the requirements of clause 4.2 (Mechanical strength and stress relief) 95/3

EA(FI)

1/91

EA(GB)

3/93

EE(Chm)

1/94

EE(Chm)5/

95

4.12.1

6.39

6.16

5.1.9

4. 7 Components may be considered to have individual fire

enclosures.

Thin tape can be used to provide a fire enclosure for

transformer windings etc, provided the tape meets V1

minimum or the complete transformer including the tape

meets Appendix A2 test. A2 will be deleted

with Amendment

196/5 EE(Chm)5/

96

6.23

4. 7 Small openings in small electromagnets, motors etc should

meet the requirements of 4.6 EA(GB)3/9

3 6.35

4. 7 Small parts of HB materials in a fire enclosure can be

accepted based on the judgement that they have adequate

spacings from ignition sources 95/20

EE(Chm)5/

95

9.19

4. 7 If the product enclosure is made of HB material there have

to be internal fire enclosures for parts where the limited

power source output criteria is not met. 95/21

EE(Chm)5/

95

9.20

4. 7. If the battery is within a fire enclosure we could accept a

material HB or better, based on the experience in EN

50091-1-1 Sect. 4.4.3.3. 99/5

EE(Chm)7/

99

9.13a

4. 7. 2.1 Parts requiring a fire enclosure

Some apparatus powered only by batteries are not required

to have a fire enclosure because beyond the batteries the

power is limited by PTC's or other devices according to

2.5. However the batteries are not power limited

therefore fire enclosure is needed.

Do you agree to consider the metal can of the battery

acting as fire enclosure?

The metal case of the battery can be considered as fire

enclosure, but the battery has also to comply with 4.3.8. 02/15

EE(Chm)

3/02

10.13

4. 7. 3 Materials of coil formers and partition walls shall fulfil the

requirement of V-2 material.

EA(FI)

1/91

EE(Chm)1/

94

4.12.3

6.14

4. 7. 3.2 Liquid crystal display (LCD) is tested as a "sandwich" and it

shall fulfil the requirement of a fire enclosure. EA(FI)

1/91 4.12.34. 7. 3.2 Enclosures of a keyboard or similar devices (e.g. mouse,

trackball) can be accepted to be made of material class HB

based on abnormal test. 95/24

EE(Chm)5/

95

9.27

4. 7. 3.2 The 13mm requirement of clause 4.7.3.2 is not relevant to

the requirements of clause 4.6. EA(GB)3/9

3 6.22

4. 7. 3.2 Thin metal foil may be used in the construction of a fire

enclosure (on HB material) provided:

1. The complete enclosure shall be tested to Appendix A1

or A2.

2. The foil covers all areas where there is a source of

ignition.

The use of metalised coating sprayed on the inside of an

enclosure made of HB-material is also acceptable provided

the tests according to Appendix A1 or A2 are met There is no

mechanical

strength

requirement on the

foil other than that

for the enclosure.

EA(GB)3/9

3

EE(Chm)1/

94

6.23

6.15

4. 7. 3.2 Materials of Fire Enclosure

LCD projectors (typical weight 1 - 5 Kg, intended for

ceiling mounting and/or transportable use together with

notebook computers) being evaluated, offers a ceiling

mount accessory kit. The kit has two major parts: one

piece mounts to the ceiling with permanent fasteners, the

other piece attaches to the projector with screws. Both

halves go together by aligning each half to a specified

feature and twisting them into position. The halves are

locked into place by turning knurled screws with finger

pressure. Mounting and un-mounting the units do not

require the use of tools.

Do the delegates agree that if the projector can be

fixed to the ceiling by any manner, even without

requiring the use of tools, the product must be

considered as Fixed and therefore the fire enclosure

must be rated 94-5V ?

For projectors specified by the manufacturer for ceiling

mounting, with or without a tool, the fire enclosure must be

rated 5V or better. 02/16

EE(Chm)

3/02

10.13

5. 3 Fault condition tests shall be carried out with 16 A

installation fuses. EA(FI)

1/91 4.11.1

5. 3 Fault condition tests shall be considered and they have to

be done even in the secondary circuit, if there is a risk of

damage to supplementary or reinforced insulation. EA(FI)

3/91 3.5

5. 3 According to EN 60127 a fuse will not break within 30

minutes at less than 2.1 times the rated current. Therefore,

if the current through the fuse does not exceed this value

after the failure is introduced, the fuse will not blow and the

test is run until steady state conditions are obtained 95/5

EE(Chm)5/

95

5.1.17

5. 3 PTC resistors which are certified according to Publ. IEC

60738-1 need not be short circuited under fault conditions 97/7

EE(Chm)5/

97

9.19

5. 3 Components can be short-circuited whether they are

separately approved or not. However, if a component

complies with requirements for reinforced insulation, it shall

not be short-circuited. EA(FI)

1/91 4.11.1

5. 3. 8 Higher temperature rises than 300°C can be accepted if the

manufacturer has proved that the material in question

withstands the temperature. EA(FI)

3/91 3.56.

6. 1

2.

The figure shows a circuitry which is connected to a Telecommu-nication

network.

Based on the network a TNV 1 situation applies.

T1 is a separation transformer which withstands 1500 Vac ES test.

This transformer is due to a functional concept bridged by a resistor of 38

Kohm to earth and by another resitor of 38 kohm to a 48 Vdc circuit which

only has functional insulation to SELV (e.g. a RS 232 communication port)

The equipment is pluggable type-A but will only be installed by a Service

Person and the installation instructions require it to be connected to an

earthed socket outlet.

So for the protection of Telecom network users from hazards in the

equipment the exclusions of 6.1.2.2 applies.

which means the resistor of 38 Kohm to earth is allowed for this

application and can be accepted without ES test

For the resistor to the 48 Vdc circuitry cl 6.2 applies (protection of

equipment users from overvoltages on telecom networks )

In this case there is only functional insulation to SELVand the circuit does

not withstand the ES test between the connection for telecom network and

RS-232 connector (SELV)

Cl. 6.2.1 says the following

equipment shall provide adequate electrical separation between a TNV-1

CIRCUIT or a TNV-3

CIRCUIT and the following parts of the equipment.

a) Unearthed conductive parts and non-conductive parts of the equipment

expected to be held or touched during normal use (for example, a

telephone handset or a keyboard).

b) Parts and circuitry that can be touched by the test finger, figure 2A (see

2.1.1.1), except contacts of connectors that cannot be touched by the

test probe, figure 2C (see 2.1.1.1).

c) An SELV CIRCUIT, a TNV-2 CIRCUIT or a LIMITED CURRENT

CIRCUIT provided for connection of other equipment. The requirement

for separation applies whether or not this circuit is accessible.

These requirements do not apply where circuit analysis and equipment

investigation indicate

that safety is assured by other means, for example, between two circuits

each of which has a

permanent connection to protective earth.

Question:

Is it necessary for compliance to perform the test acc to 6.2.2.1 (impulse

test) or 6.2.2.2 (steady state ES test), or can we accept this situation without

testing if the following applies:

Separate approved surge suppressors are provided which limit an incoming

transient voltage to a level of max 70 V before the resistor. Circuit analysis

shows that this will never result in a hazardous voltage on the RS 232 port

(SELV).

If it is obvious that the product will fulfil the requirements no

test is necessary.

Otherwise the tests have to be performed due to the

requirements of 6.2.2.3.

Confirmed by

TC108-WG7

03/4

EE(Chm)